Home/Products/Cast-Resin Dry-Type

Cast-Resin Dry-Type
Transformers.

Up to 12 MVA / 34.5 kV — for indoor substations, data centers, hospitals, and any installation where fire load or oil leakage is unacceptable. Designed to IEEE C57.12.01, delivered in 4 to 6 months.

CaptionCast-resin 24 kV unit, NEMA TR1 spec, IP31 enclosure — staged for IT room delivery.
Asset refDT-024-2500-AZ-118
Voltage Class Up to 34.5 kV 12 / 15 / 25 / 34.5 kV grid
Power Rating 100 kVA – 12 MVA Custom-engineered per project
Lead Time 4 – 6 mo Standard scope, IEEE-spec design
Insulation F / H / C Cast-resin · NOMEX · glass fiber
01 · Applications/ where dry-type is the answer

For installations where oil
is not an option.

Epoxy-encapsulated windings eliminate fire load and oil leakage risk — required where life safety, sterile environments, or vertical real estate makes oil-filled equipment a non-starter.

App · 01

Data center IT rooms

In-room MV-LV step-down to UPS and PDU rails. Low fire load, no oil containment required.

App · 02

Hospitals & life-safety

Main feeders and ICU panels. Required where oil leakage or fire risk near patients is unacceptable.

App · 03

High-rise buildings

Tenant MV substations on intermediate floors. NEC and IBC fire-rating compatibility.

App · 04

Subway & rail tunnels

Underground traction substations. Confined spaces with strict fire-load and ventilation constraints.

App · 05

Offshore platforms

Wind, oil & gas. Sealed enclosures rated for salt-spray and marine atmospheres.

App · 06

Industrial plant subs

Indoor MV substations in chemical, pharma, and food plants. Cleanroom-compatible.

02 · Voltage map/ class · US grid · typical use

Three voltage tiers,
three application bands.

Voltage class drives enclosure, BIL, and insulation choice. Pick the closest US grid match — we'll confirm BIL ladder and tap arrangement during the spec phase.

Up to 12kV
12 / 15 kV
Building MV-LV substations · data center IT rooms · in-floor tenant subs
F-class
15 – 25kV
25 kV
Industrial plant substations · hospital main feeders · subway traction
F / H
25 – 34.5kV
34.5 kV
Indoor utility substations · offshore platforms · large industrial mains
H / C
03 · Build + standards/ encapsulation · testing

Vacuum-encapsulated.
IEEE-tested.

Cast-resin (epoxy) encapsulation under vacuum. Routine and type tests per IEEE C57.12.91. Same HV test lab as the oil-immersed line.

Process · 0101

Winding & encapsulation

  • Cast-resin (epoxy) encapsulation under vacuum
  • Copper or aluminum foil / wire windings
  • NOMEX and glass-fiber insulation for high-temperature classes
  • Thermal monitoring sensors integrated as standard
Process · 0202

Testing & certification

  • HighVolt + OMICRON measurement systems
  • Routine + type tests per IEEE C57.12.91
  • KEMA + CESI third-party type tests on serial production
  • Project-specific IEEE reports under each US contract
Designed to
IEEE C57.12.01 NEMA TR1 ANSI IEC 60076-11
ISO 90011400145001
04 · Related/ paired lines

If oil is acceptable.

For higher voltages or larger ratings where indoor-only constraints don't apply, the oil-immersed lines cover the rest of the envelope.

05 · Request a quote

Indoor sub on
your drawings?

Send the load list, ambient conditions, and BIL ladder. Our engineering team confirms insulation class, enclosure rating, and lead time within one business day.

VoltageUp to 34.5 kV
RatingUp to 12 MVA
Lead time4 – 6 months